Which AI batch review software can be validated for GMP use?
By Savi C., Co-Founder · Published Nov 25, 2026
What makes AI review software validatable
Requirement
Controlled models
What to look for
Versioned models, with any adaptation to your records documented and kept inside your deployment
Requirement
Clear intended use
What to look for
The tool proposes and a person decides. It cannot release, reject or close anything itself
Requirement
Testable performance
What to look for
You can run it on your own reviewed records and measure findings, misses and false flags
Requirement
Traceable output
What to look for
Every flag links to its source, and every reviewer decision is recorded with who and when
Requirement
Controlled updates
What to look for
You are told about new model versions in advance, with evidence, and choose when to install
Requirement
Vendor documentation
What to look for
Intended use, testing approach and evidence you can use in your own risk-based validation
When a change needs what
A starting point for your change control assessment. Your procedures and risk assessment decide the final scope.
Change
New model version for reading or checking records
Typical response
Change control, impact assessment, and re-running performance tests on representative records before use
Change
New check configured from your SOPs or specifications
Typical response
Change control and testing of the new check, as for any configuration change
Change
Change to a specification limit used by a check
Typical response
Confirm the next review uses the new value, under your normal change process
Change
Interface or reporting change with no effect on results
Typical response
Change control with a lighter, risk-based assessment
How AI review holds up in an FDA inspection
Investigators look at your quality system: whether the tool was validated for its intended use, whether it is under change control, and whether the quality unit still made the decision. Under 21 CFR 211.192 the quality control unit reviews and approves production and control records before release, and 21 CFR 211.68 allows computer systems in CGMP work when their performance is checked and changes are controlled.
A probabilistic model fits that framework when it proposes and a person decides. Keep the performance testing behind each model version, the change record for every update, and the reviewer's decision on every flag. EU guidance on AI in GMP is still developing: draft Annex 22 is not in force, so build to the currently effective Annex 11 and treat the drafts as direction.
How Litewave fits
Litewave never trains a shared model on customer data, and customer data is never sent to third-party model providers. Its handwriting engine learns your operators inside your own deployment, and what it learns stays there. Litewave proposes and qualified people approve: it never releases a batch on its own, every flag links to its source page, and it records who decided what, on what evidence, and when.
The validation documentation you need to qualify Litewave in your environment is scoped as part of the commercial agreement. In air-gapped deployments, updates and model packages ship on signed media. For the full method, see our guide How do you validate an AI tool in a GxP environment?
Questions we get asked
Does AI software need revalidation every time the model changes?
Every model change goes through change control. The change is assessed for risk and tested in proportion before use, which for a new reading or checking model usually means re-running performance tests on representative records.
Can a vendor hand us a validation package?
A vendor can provide documentation and test evidence to support your validation, but validation for your intended use is your responsibility. Ask exactly what is included before you buy.
Is a model that keeps learning in production acceptable in GMP?
Only if the learning is controlled. You need to know what can change, how performance is monitored, and how changes are documented. A model whose behaviour changes without anyone knowing cannot be kept in a validated state.
Sources
- 21 CFR 211.68, Automatic, mechanical, and electronic equipment (eCFR)
- 21 CFR 211.192, Production record review (eCFR)
- 21 CFR Part 11, Electronic records; electronic signatures (eCFR)
- EudraLex Volume 4, Annex 11, Computerised Systems
- ISPE, GAMP 5 Guide, second edition
- ISPE GAMP Guide: Artificial Intelligence (July 2025)
- FDA, Computer Software Assurance for Production and Quality Management System Software (February 2026)
- European Commission, stakeholders consultation on EU GMP Chapter 4, Annex 11 and new Annex 22