What the regulation asks for
Section 111.255 requires a batch production record each time a batch is manufactured. It must contain complete information about the production and control of the batch, accurately follow the master manufacturing record, and show that each step was performed. Section 111.260 then lists the contents, from (a) through (n).
Section 111.123 sets out what quality control must do. That includes reviewing and approving all batch production records, reviewing required monitoring, conducting any required material review and making the disposition decision, approving or rejecting reprocessing, determining whether in-process and finished batch specifications are met, and approving and releasing, or rejecting, each finished batch. Paragraph (b) lists batches that quality control must not release, including any batch containing a component that does not meet its identity specification.
What 111.260 requires the record to contain
Requirement
Batch, lot or control number (a)
What the reviewer confirms
Finished batch number assigned, and each packaged lot traceable to it
Requirement
Equipment and processing lines (b), cleaning and maintenance (c)
What the reviewer confirms
Equipment identified, with cleaning and maintenance dates recorded or cross-referenced
Requirement
Component, packaging and label identifiers (d), identity and weight of each component (e)
What the reviewer confirms
Every lot number and weight present and matching the master record
Requirement
Actual yield and percent of theoretical yield (f)
What the reviewer confirms
Yields stated at the appropriate phases and inside the expected range
Requirement
Monitoring results (g), in-process test results (h)
What the reviewer confirms
Actual results recorded, not only a pass mark, and inside limits
Requirement
Documentation that the finished product meets specifications (i)
What the reviewer confirms
Finished product results recorded against the specifications set under 111.70
Requirement
Manufacturing documentation at the time of performance (j)
What the reviewer confirms
Date of each step, initials of the people who weighed, verified weights, added components and verified additions
Requirement
Packaging and labeling documentation (k)
What the reviewer confirms
Packaging and label lots and quantities, label reconciliation where required, an actual or representative label
Requirement
Quality control review and decisions (l), material review (m), reprocessing (n)
What the reviewer confirms
Each decision recorded when it was made, by the person who made it
Batch record review checklist
Before the batch is reviewed
- The batch record was issued from the current approved master manufacturing record
- Each dietary ingredient had at least one identity test before use, as 111.75(a) requires, unless FDA granted an exemption
- Other components were confirmed by testing or by a qualified supplier certificate of analysis
Manufacturing and packaging
- Every step completed, dated and initialed, including the second-person verification of weights and additions
- Calculations and yields carried through correctly
- Monitoring and in-process results recorded as actual values
- Labels issued, used and returned reconciled, with any discrepancy explained
Decisions and release
- Any material review, reprocessing or rejection decision documented and signed by quality control
- Finished batch results meet every product specification, with nothing pending
- The release decision recorded only after the rest of the record is complete
Where reviews tend to slip
The requirements that are easiest to miss are the ones about timing. Section 111.260 asks for manufacturing, packaging and quality control documentation made at the time of performance, so a step dated after the fact, or a set of initials added at the end of a shift, is a finding even when the value itself is correct. The second-person checks are another weak spot: the record must show who weighed or measured each component and who verified it, and who added each component and who verified the addition.
Cross-references also need checking. The regulation allows equipment cleaning and in-process test results to be cross-referenced rather than copied into the batch record, but the reviewer still has to confirm that the referenced record exists, covers this batch and is complete.
How Litewave fits
Litewave reads paper or electronic records, checks every entry against your master record and specifications, and shows QA only the exceptions, each linked to the page it came from. Litewave proposes, qualified people approve, and quality control still makes every release decision. Our published results come from pharmaceutical manufacturing, at a leading global generic API manufacturer, and we do not claim results in dietary supplements until a supplement customer has agreed to publish them.
Questions we get asked
Can a supplier certificate replace identity testing of a dietary ingredient?
Not by default. Section 111.75(a) requires at least one appropriate test or examination to verify the identity of each dietary ingredient, unless FDA has granted an exemption on petition. Supplier certificates can be used for other components once the supplier is qualified, and must be periodically reconfirmed.
How long must batch production records be kept?
Section 111.605 requires one year past the shelf life date if you use shelf life dating, or two years beyond the date of distribution of the last batch associated with the records if you do not.
Can the batch record be electronic?
Yes. Part 111 allows original records, true copies or electronic records, and electronic records must meet 21 CFR Part 11.
Sources
- 21 CFR 111.75, Component identity and specification testing (eCFR)
- 21 CFR 111.123, Quality control operations for master manufacturing records, batch production records and manufacturing operations (eCFR)
- 21 CFR 111.255, Batch production record requirements (eCFR)
- 21 CFR 111.260, Batch production record contents (eCFR)
- 21 CFR 111.605, Record retention and form (eCFR)