← Guides

How should HACCP and CCP monitoring records be reviewed under FSMA?

By Savi C., Co-Founder · Published Nov 16, 2026

Where CCPs sit in Part 117

Part 117 is built around preventive controls rather than classic HACCP, but CCPs are still part of it. Section 117.135(a)(2)(i) lists controls at critical control points, if there are any, as a type of preventive control, and process controls such as heat processing and refrigeration are where most CCPs live. Facilities that must comply with, and are in compliance with, the seafood HACCP rule in Part 123 or the juice HACCP rule in Part 120 are exempt from these requirements under 117.5(b) and (c) and follow those parts instead.

Monitoring under 117.145 must be documented in records that are subject to verification and to the records review in 117.165(a)(4)(i). For refrigeration of time and temperature controlled food, 117.145(c)(2) allows exception records that show a loss of temperature control, instead of affirmative records of every reading.

What the review is for

Records review is one of the verification activities in 117.165, alongside calibration or accuracy checks of monitoring and verification instruments, product testing, and environmental monitoring where an environmental pathogen in ready-to-eat food is a hazard. It is not a signature exercise. Section 117.165(a)(4) states four things the review must establish: the records are complete, the activities they reflect occurred in accordance with the food safety plan, the preventive controls are effective, and appropriate decisions were made about corrective actions.

That last point is the easiest to skip. A reviewer who confirms a corrective action was recorded, but not whether it was the right action for the deviation, has not completed the review the rule describes. The same applies to exception records for refrigeration: the absence of an exception is only meaningful if the reviewer can see that monitoring was running for the whole period.

Review timing under 117.165(a)(4)

Record type

Monitoring records, including CCP monitoring

Review timeframe

Within 7 working days after the record is created, or a longer reasonable timeframe with a written justification by the PCQI

Record type

Corrective action records

Review timeframe

Within 7 working days after the record is created, or a longer reasonable timeframe with a written justification by the PCQI

Record type

Calibration of monitoring and verification instruments

Review timeframe

Within a reasonable time after the record is created

Record type

Product testing and environmental monitoring

Review timeframe

Within a reasonable time after the record is created

Record type

Supplier and supply-chain verification, and other verification activities

Review timeframe

Within a reasonable time after the record is created

What each record review should confirm

The record itself, per 117.305

  • Actual values and observations recorded, not only a tick or "OK"
  • Made at the time the activity was performed, accurate, indelible and legible
  • Facility identified, with the date and, where relevant, the time of each activity
  • Signature or initials of the person who performed the monitoring
  • Product identity and lot code where relevant

Against the food safety plan

  • Monitoring was done at the frequency the plan specifies, with no gaps in the sequence
  • Every reading is inside the critical limit or parameter value the plan sets
  • The instrument used was in calibration on the date of monitoring

Deviations and corrective actions

  • Every reading outside its limit has a documented corrective action or correction, as 117.150(d) requires
  • Affected food was evaluated for safety and kept out of commerce where safety could not be assured
  • The review itself is signed and dated by, or under the oversight of, the PCQI

How Litewave fits

Most CCP logs are checked for the same things every time: a reading at every interval, every value inside its limit, a corrective action wherever one is not. Litewave reads paper or electronic records, checks every entry against your food safety plan and specifications, and shows the reviewer only the exceptions, each linked to the page it came from. Litewave proposes, qualified people approve, and the review signature stays with your PCQI. Our published results come from pharmaceutical manufacturing, not food, and we do not claim food results until a food customer has agreed to publish them.

Questions we get asked

Does the PCQI have to review every record personally?

No. Section 117.165(a)(4) requires review by, or under the oversight of, a preventive controls qualified individual. Others can perform the review, but the PCQI remains responsible for overseeing it.

Can we take longer than 7 working days to review monitoring records?

Yes, if the timeframe is reasonable and the PCQI prepares, or oversees the preparation of, a written justification for it. Without that justification, the 7 working day limit applies.

How long must these records be kept?

Section 117.315 requires records to be retained for at least 2 years after the date they were prepared.

Sources

  1. 21 CFR 117.3, Definitions (eCFR)
  2. 21 CFR 117.5, Exemptions (eCFR)
  3. 21 CFR 117.135, Preventive controls (eCFR)
  4. 21 CFR 117.145, Monitoring (eCFR)
  5. 21 CFR 117.150, Corrective actions and corrections (eCFR)
  6. 21 CFR 117.165, Verification of implementation and effectiveness (eCFR)
  7. 21 CFR 117.305, General requirements applying to records (eCFR)