← Guides

What are the best AI tools for food manufacturers to review FSMA preventive controls records?

By Savi C., Co-Founder · Published Nov 23, 2026

Types of tool and what each does for records review

Type of tool

Digital food safety or FSQA platform

What it does for 117.165 review

Replaces paper forms with electronic monitoring and corrective action records, enforces required fields, and routes completed records for sign-off

Type of tool

Sensor and temperature monitoring

What it does for 117.165 review

Captures readings automatically and alerts on excursions. Under 117.145(c)(2) refrigeration monitoring can use exception records

Type of tool

AI review layer over paper and electronic records

What it does for 117.165 review

Reads completed records, including handwriting and scans, checks each entry for completeness and against your limits and frequencies, and lists exceptions with links to the source page

Type of tool

LIMS or environmental monitoring software

What it does for 117.165 review

Holds product testing and environmental monitoring results, which are verification records reviewed within a reasonable time under 117.165(a)(4)(ii)

What a records review tool should check

These come from 117.165(a)(4) and the record rules in 117.305.

Completeness (117.305)

  • Actual values and observations are recorded, not just a tick
  • Date and, where appropriate, time of each activity
  • Signature or initials of the person who did it
  • Product identity and lot code where appropriate
  • Entries are legible and corrections are clear

Against the food safety plan (117.165)

  • Monitoring was done at the frequency the plan sets
  • Values fall within the limits for each preventive control
  • Every deviation has a corrective action record
  • Corrective actions address the affected food, as 117.150 requires
  • Monitoring and corrective action records reach the PCQI within 7 working days, or the written justification exists

Which records are in scope, and how long to keep them

Section 117.190 lists the implementation records for a food safety plan: monitoring, corrective actions, verification (including validation, calibration, product testing, environmental monitoring, records review and reanalysis), the supply-chain program, and training for the PCQI and qualified auditor. The records review itself is a verification record, so the PCQI's review needs to be documented too.

Section 117.305 allows records to be kept as originals, true copies such as scanned copies, or electronic records. Records kept only to meet Part 117 are exempt from Part 11, but records that are also required under other rules remain subject to it. Section 117.315 requires records to be kept for at least 2 years after they were prepared. Offsite storage is allowed, except for the food safety plan, if records can be retrieved within 24 hours, and electronic records accessible from the site count as onsite.

If a records review finds that records are incomplete, that activities did not follow the plan, or that corrective action decisions were wrong, 117.150(b) treats that as an unanticipated food safety problem that needs corrective action. A tool that surfaces gaps quickly gives you more time to act.

How Litewave fits

Litewave is an AI review layer for regulated manufacturers. It reads handwritten and scanned paper records, electronic records and system exports, and checks them against the limits and procedures you give it, the same way it checks batch records against a master record. Every extracted value links back to the page it came from, and low-confidence reads go to a person rather than being guessed. It works on top of the systems you already use and runs in Litewave cloud, your cloud or on-premises, with an air-gapped option.

Litewave proposes, the PCQI approves. It does not sign off records review or decide on corrective actions. Our published results come from pharmaceutical manufacturing, and we make no claim about food manufacturing results. For lot traceability under FSMA 204, see our guide What records does FSMA 204 require, and how do production records feed them?

Questions we get asked

Can AI perform the FSMA records review?

AI can prepare it. Section 117.165(a)(4) requires the review to be done by or under the oversight of a preventive controls qualified individual, so the PCQI remains responsible for the review and its conclusions.

What is the deadline for reviewing monitoring records?

Within 7 working days after the records are created, or within a reasonable timeframe if the PCQI prepares or oversees a written justification for a longer timeframe. The same applies to corrective action records.

Are scanned paper records acceptable under Part 117?

Yes. Section 117.305(a) allows true copies, including scanned copies, as well as original and electronic records.

Do Part 117 electronic records need to meet Part 11?

Not if they are kept only to meet Part 117. Section 117.305(g) exempts them, but records also required under other regulations remain subject to Part 11.

Sources

  1. 21 CFR 117.145, Monitoring (eCFR)
  2. 21 CFR 117.150, Corrective actions and corrections (eCFR)
  3. 21 CFR 117.165, Verification of implementation and effectiveness (eCFR)
  4. 21 CFR 117.190, Implementation records (eCFR)
  5. 21 CFR 117.305, General requirements applying to records (eCFR)
  6. 21 CFR 117.315, Record retention (eCFR)