← Guides

Which software helps Canadian natural health product manufacturers meet GMP requirements?

By Savi C., Co-Founder · Published Nov 23, 2026

Part 3 requirements and the software that supports them

Requirement

Section 44: each product complies with its specifications for purity, identity, quantity per dosage unit and, where claimed, potency. A quality assurance person approves the specifications

Software that supports it

A specification library with approval history, and a test record or LIMS that compares each result to its tolerance

Requirement

Section 49: activities follow standard operating procedures

Software that supports it

QMS document control with approval and version history

Requirement

Section 50: a system of control that permits rapid and complete recall of every lot or batch made available for sale

Software that supports it

ERP or inventory lot tracking that links ingredient lots to finished lots and to customers

Requirement

Section 51(1)(b): investigate and record every quality complaint and take corrective action if needed

Software that supports it

QMS complaint and CAPA modules linked to the affected lot

Requirement

Section 51(2) and (4): a quality assurance person approves materials before use and every lot or batch before sale

Software that supports it

A review tool that checks incoming certificates and batch records and lists the exceptions. Approval is a recorded human decision

Requirement

Section 53: master production document, ingredient lists, raw material and lot test records, specifications, and records showing each lot was made to Part 3

Software that supports it

A records system that can retrieve every record for a lot, paper or electronic

Requirement

Section 58: keep lot records for one year after the product's expiry date

Software that supports it

Retention rules by lot and expiry date

What GUI-0158 expects of records

GUI-0158 version 4.0 was published on September 4, 2025 and took effect on March 4, 2026, replacing version 3. Health Canada reorganized it to follow the order of the regulations and it includes guidance on CAPA plans, quality agreements, recall systems and mock recalls, and reduced and rotational testing.

On records, the guide asks for good documentation practices: records that are reliable, complete, consistent and accurate, no backdating or postdating, and any change to a document explained, signed and dated. For electronic records it asks you to back them up, keep an audit trail of changes and deletions, and allow only authorized personnel to change them. Any software you choose should make those expectations easier to meet, not harder.

If you also sell into the US as dietary supplements, FDA's 21 CFR Part 111 applies there. It is a separate rule with its own record and review requirements, so map each set of requirements on its own. Our guide Part 111 batch record review covers the US side.

Questions to ask any vendor

Records

  • Can it work with our records as they are, including handwritten batch records and scanned supplier certificates?
  • Does it check results against our approved specifications and tolerances under section 44?
  • Does every flag link to its source page?
  • Can we pull every record for a lot quickly enough to support a recall under section 50?

Control

  • Does the quality assurance person always make and record the approval under section 51?
  • Does it keep an audit trail of changes and restrict who can change records, as GUI-0158 asks?
  • Does it run on top of our existing QMS and ERP, or require us to move everything first?
  • Can it be deployed where our data policy requires, including on-premises?

How Litewave fits

Litewave is an AI review layer for regulated manufacturers. It reads handwritten and scanned paper records, electronic batch records and system exports, and checks executed batch records against your master production document and specifications. It also compares incoming certificates of analysis against your approved specifications and supplier history, and flags missing, changed or out-of-spec results, in whatever layout the supplier sends. Every extracted value links back to its source page, and low-confidence reads go to a person.

Litewave is not a QMS and does not file anything with Health Canada. It works on top of your existing systems and runs in Litewave cloud, your cloud or on-premises, with an air-gapped option. Litewave proposes, qualified people approve. It never releases a lot on its own. Our published results come from pharmaceutical manufacturing, and we make no claim about natural health product results.

Questions we get asked

Who approves an NHP lot for sale in Canada?

A quality assurance person. Section 51(4) of the Natural Health Products Regulations requires every lot or batch to be approved by a quality assurance person before it is made available for sale.

How long must NHP batch records be kept?

Section 58 requires any record that relates to a lot or batch to be kept for one year following the expiry date of the product it relates to.

Which version of GUI-0158 applies now?

Version 4.0. Health Canada published it on September 4, 2025, and it took effect on March 4, 2026, when version 3 was removed.

Are NHPs covered by drug GMP under GUI-0001?

No. Natural health products have their own GMP requirements in Part 3 of the Natural Health Products Regulations, explained in GUI-0158.

Sources

  1. Natural Health Products Regulations, full text including Part 3, sections 43 to 62 (Justice Laws)
  2. Natural Health Products Regulations, section 51, Quality assurance (Justice Laws)
  3. Natural Health Products Regulations, section 53, Records for manufacturers (Justice Laws)
  4. Health Canada, Good manufacturing practices guide for natural health products (GUI-0158), version 4.0
  5. Health Canada, GUI-0158 version 4 notice (September 4, 2025)
  6. Health Canada, GUI-0158 guidance on sections 52 to 62, including records
  7. 21 CFR Part 111, CGMP for dietary supplements (eCFR)