← Guides

How do you choose AI manufacturing software for raw-material certificate management?

By Savi C., Co-Founder · Published Nov 17, 2026

What certificate management has to cover

A certificate of analysis is only useful when it is checked against three things: your specification for that material, the physical lot that arrived, and what the same supplier has reported before. A certificate that is complete and in specification can still hide a problem if the supplier has dropped a test, widened a limit, or started reporting results that drift toward the edge of your range.

For cosmetics, the expectations come from ISO 22716, which most US plants follow while the MoCRA GMP rule remains unproposed. It asks for raw materials to be checked against acceptance criteria before release, without setting a specific identity testing rule. Many plants still run identity checks on higher-risk materials because customers or certifiers ask for it.

Drug and supplement rules are specific. 21 CFR 211.84 lets a drug manufacturer accept a supplier report of analysis only with at least one specific identity test and established supplier reliability. Our guide "How should incoming CoAs be reviewed under 21 CFR 211.84?" covers that rule and a per-certificate checklist in detail. Under 21 CFR 111.75, a supplement manufacturer must run an identity test on each dietary ingredient, and may rely on a certificate for other components only if the supplier is qualified, the certificate shows methods, limits and actual results, the qualification is documented and periodically reconfirmed, and quality control approves the basis for it.

What to compare between tools

Capability

Reading certificates

What good looks like

Reads digital PDFs, scans and emailed images in each supplier's own layout, without building a template per supplier

Capability

Specification match

What good looks like

Checks every test, method and limit against your approved specification at its current revision

Capability

Missing tests

What good looks like

Flags tests your specification requires that the certificate does not report

Capability

Limits and results

What good looks like

Flags supplier limits wider than yours and results reported only as "complies" where you need a number

Capability

Supplier history

What good looks like

Compares each lot with the supplier's earlier lots and shows trends, not just this lot in isolation

Capability

Identity testing

What good looks like

Shows whether your own identity test was done and passed, and keeps it separate from the certificate check

Capability

Evidence and control

What good looks like

Links every flag to its source page and leaves release with your quality unit

Before you sign

Test it on your own documents

  • Run a month of real certificates, including scans and ones with known problems
  • Check how many issues it finds that your team found, and how many it adds
  • Change a specification revision and confirm the next check uses it

Fit with your system

  • Confirm where specifications and the approved supplier list come from, and how they stay in sync
  • Confirm certificates and results remain retrievable for your required retention period
  • Confirm it works with your QMS, ERP or LIMS rather than replacing them

How Litewave fits

Litewave's Supplier Quality & CoA Review reads incoming certificates of analysis, on paper or electronic, compares them against your approved specifications and supplier history, and flags missing, changed or out-of-specification results. Each flag links to the page it came from, so QA reviews exceptions instead of every line. It works on top of your existing QMS, ERP and LIMS. Litewave proposes, qualified people approve, and the release decision stays with your quality unit.

Our published results come from pharmaceutical manufacturing, and we make no claim about cosmetics or supplement results.

Questions we get asked

Can a CoA replace identity testing?

Not for drug components under 21 CFR 211.84 or dietary ingredients under 21 CFR 111.75. Both require your own identity test. For cosmetics, ISO 22716 sets no specific identity testing rule, so your procedures and customer requirements decide.

Is a document management system enough for certificates?

It stores and controls them. It does not usually read each certificate and compare it with your specification and supplier history. That comparison is the step AI software is for.

How long should raw-material certificates be kept?

It depends on the sector. For drugs, 21 CFR 211.180(b) requires component records for at least 1 year after the expiration date of the last lot using the component, or 3 years after distribution for certain OTC products without expiration dating. For supplements, 21 CFR 111.605 sets 1 year past shelf life or 2 years past distribution of the last batch. For cosmetics, set the period in your procedures in line with shelf life and customer terms.

Sources

  1. ISO 22716:2007, Cosmetics, Good Manufacturing Practices
  2. 21 CFR 211.84, Testing and approval or rejection of components (eCFR)
  3. 21 CFR 111.75, Determining whether specifications are met (eCFR)
  4. 21 CFR 211.180, Records and reports, general requirements (eCFR)
  5. 21 CFR 111.605, Requirements for records you make and keep (eCFR)