What AI quality software fits a mid-size manufacturer without an electronic batch record system?
By Savi C., Co-Founder · Published Nov 23, 2026
Selection criteria for a mid-size plant
Use these as rows in a scoring sheet. Ask each vendor to show, not tell.
Criterion
Works on paper and exports
What good looks like
Reads handwritten and scanned records, plus exports from LIMS, ERP and equipment, without asking you to move data into its own system first
Criterion
No template build
What good looks like
Reviews a new product from its master record and executed record, without weeks of mapping each form into a digital template
Criterion
Checks against your rules
What good looks like
Uses your master record, specifications and release criteria as the basis for every check
Criterion
Traceable findings
What good looks like
Every value and every flag links to the page or field it came from, so a reviewer can confirm it in seconds
Criterion
Human decision
What good looks like
The tool proposes and a qualified person accepts or rejects each finding, with the decision recorded
Criterion
Deployment options
What good looks like
Vendor cloud, your cloud or on-premises, with an air-gapped option if your data policy needs one
Criterion
Validation effort per intended use
What good looks like
The vendor describes the intended use, how performance was tested, and what evidence you receive, so your effort scales with risk
Criterion
Load on a small IT team
What good looks like
Few integrations needed to start, clear user and access controls, and a named contact for support and change notices
Validation effort, sized to intended use
Mid-size plants often overestimate or underestimate validation. The useful starting point is intended use. A tool that reads records and proposes exceptions for a person to review is in a different risk position from one that decides acceptability on its own. FDA's Computer Software Assurance guidance treats software that determines product acceptability with limited or no human review as higher risk, and says its risk framework can be applied to AI and machine learning tools. Its direct scope is device production and quality management system software under Part 820, but drug manufacturers often use its reasoning as a reference.
For drug manufacturers, 21 CFR 211.68 asks that computer systems perform their function satisfactorily and that input and output be checked for accuracy, with the degree of checking based on the system's complexity and reliability. FDA's data integrity guidance adds that each CGMP workflow on a computer system should be validated. Where the tool keeps electronic records or signatures that you rely on, 21 CFR Part 11 applies. Our guide How do you validate an AI tool in a GxP environment? covers what a validation package should contain.
How Litewave fits
Litewave is an AI review layer for regulated manufacturers. It works on top of your existing QMS, MES, LIMS, ERP and paper records, and is not a QMS replacement. It reads handwritten and scanned paper records, electronic batch records and system exports. Every extracted value links back to the page it came from, and low-confidence reads route to a person.
Batch Review & Release checks executed batch records or device history records against the master record, specifications and release criteria, and produces a review-by-exception file for QA. Supplier Quality & CoA Review compares incoming certificates against approved specifications and supplier history. Deviation Investigations builds the event timeline from source records and proposes root cause and CAPA candidates for human review. A new product can be reviewed without building a digital template first.
Litewave runs in Litewave cloud, your cloud or on-premises, with an air-gapped option in which no data leaves your network. Litewave proposes, qualified people approve. Our published results come from pharmaceutical manufacturing, where a leading global generic API manufacturer cut batch disposition time by 85%, and we make no claim about results in other industries.
Questions we get asked
Should a mid-size plant buy an EBR first?
Not necessarily. An EBR controls execution once every master record is rebuilt in it. AI review checks the records you already produce, including paper. Our guide AI record review vs an EBR or MES: do you need both? covers when each comes first.
Does the FDA CSA guidance apply to drug manufacturers?
Its scope is software used in device production or the quality management system under Part 820. Drug manufacturers under Part 211 are not its direct audience, although many use its risk-based reasoning alongside 21 CFR 211.68.
How much IT support does AI quality software need?
It depends on the deployment. A cloud tool that reads uploaded scans and exports needs little to start. On-premises or air-gapped installs need more from IT. Ask each vendor what your team must provide before the first record is reviewed.
Sources
- FDA, Computer Software Assurance for Production and Quality Management System Software (February 2026)
- 21 CFR 211.68, Automatic, mechanical and electronic equipment (eCFR)
- 21 CFR 820.10, Requirements for a quality management system (eCFR)
- 21 CFR Part 11, Electronic records; electronic signatures (eCFR)
- FDA, Data Integrity and Compliance With Drug CGMP: Questions and Answers (December 2018)
- Litewave case study, batch disposition at a leading global generic API manufacturer